WMV-670A Veterinary Portable X Ray System
Features
4kw 70Ma,portable design,removable head portable x ray machine.
6 periods of digital LED display
48 kinds of presupposed anatomy memory pattern choice
Accuracy control method of simulation and double digital loop
High precision control of tube voltage,tube current
No consumables, suitable for pet hospitals and other animal diagnosis and treatment machines
Failure self-protection,self-diagnosis
X ray tube ball into the lead cylinder,effectively shielding radiation leak,
more environmental protection and operator safety
Remote control exposure capability for the animal weight less than 40kg
12months warranty
PRODUCT DETAILS
Specification
Power parameter
Input power Voltage : AC220V ± 22V,
frequency: 50/60 Hz±1Hz;
Power capacity: ≥5kVA;
Inner resistance≤0.5Ω
Maximum output power:P =110kV×36mA=4kW
Nominal power:100kV,40mA,0.1s,4kW
Frequency&range
Frequency :≥40kHz
KV adjusting range :40kV~110kV, step adjustment is 1 kV
mA adjusting range :36mA~70mA
mAs adjusting range :1mAs-200mAs,shifted adjustment
S adjusting range :0.04s~3.2s
X ray tube :Focus:0.6/1.5mm;
Anode heating capacity:76kHU
G.W/Size
Size :290×260×230 mm
Weight :18.8kg
Optional DR system
Application
The 4KW portable digital high frequency X-ray system is mainly
suitable for extremities check,especially for rescues or diagnosis in
Field operation sites,battlefields,stadiums,etc.
DR Composition
Main components | Name of components | Model/ specification | Quantity | Remark |
Portable x-ray machine | YJP040DR-A | 1 set | Standard | |
Digital detector | Rayence 1717SCC (17X17inch) | 1 set | Made-in-Korea, Standard | |
Laptop | Lenovo | 1 set | (Made-in-China), Standard | |
DR image processing software | Rayence | 1 set | (Made-in-Korea), Standard | |
Accessory equipment | Machine frame | YJF-Ⅰ | 1 set | (Made-in-China), Standard |
Optional frame |
Complete software performance and Connection
Features
Deft and concise
6 periods of digital LED display
48 kinds of presupposed anatomy memory model choices
Accuracy control method of simulation and digital double loop
High precision control of tube voltage, tube current
Failure self-protection, self-diagnosis
Specification
Model | YJP040DR-A |
Input power | Voltage: AC220V±22V Frequency: 50/60Hz±1Hz |
Maximum output power | P =110kV×36mA=4kW |
Nominal power | 100kV,40mA,0.1s,4kW |
kV adjusting range | 40kV~110kV,Continuous adjustment step 1 kV |
mA adjusting range | 36mA~60mA |
mAs adjusting range | 1mAs-190mAs, Shifted adjustment |
adjusting range | 0.04s~3.2s |
X-ray tube | Brand:Toshiba Focus :0.6/1.6mm; Anode heat capacity:76kHU |
Rayence digital detector 17X17inch | Scintilatolr:CsI Direct Deposit Pixel Matrix: 3,328X3,328 Limit resolution:Max.3.9LP/mm A/D Conversion:14bit Weight:4.1Kg |
Laptop | Model:Lenovo CPU:Intel Core i5 Memory capacity:4GB Screen size: 14 inch |
Anatomy program | 48 kinds of memory choices |
X-ray machine size | 290×260×230mm |
X-ray machine Weight | 18.8kg |
Accessory | Standard:hand switch,remote control, suitcase,machine stand |
Optional | Machine frame |